IFL-N-4-12-10STP -2033
IFL-N-4-12-10STP -2033
Downloads
- Design M12
Ordering data
| Product type description |
IFL-N-4-12-10STP -2033 |
| Article number (order number) |
101148143 |
| EAN (European Article Number) |
4030661287034 |
| eCl@ss number, version 12.0 |
27-27-40-01 |
| eCl@ss number, version 11.0 |
27-27-01-01 |
| eCl@ss number, version 9.0 |
27-27-01-01 |
| ETIM number, version 7.0 |
EC002714 |
| ETIM number, version 6.0 |
EC002714 |
General data
| Standards |
DIN VDE 0660-208 EN IEC 60947-5-2 |
| Housing construction form |
Cylinder, thread |
| Installation conditions (mechanical) |
not flush |
| Housing material |
Stainless steel |
| Active area |
Plastic |
| Material of the nuts |
Stainless steel |
| Gross weight |
30 g |
General data - Features
| Integral system diagnostics, status |
Yes |
| Number of cable wires |
3 |
Mechanical data - Switching distances
| Nominal switching distance Sn |
4 mm |
| Note (switching distance) |
All switching distances in accordance EN IEC 60947-5-2 |
Mechanical data - Connection technique
| Length of cable |
2 m |
| Termination |
Connector M12 |
Mechanical data - Dimensions
| ISO thread of the sensor |
M12 |
| Length of sensor |
65 mm |
Ambient conditions
| IP Degree of protection |
IP67 |
| Ambient temperature |
-25 ... +85 °C |
| Resistance to vibrations |
10 … 55 Hz, amplitude 1 mm |
| Restistance to shock |
30 g / 11 ms |
| Protection class |
II |
Electrical data
| Operating voltage |
15 ... 34 VDC |
| Type of voltage range |
DC |
| No-load supply current I0, typical |
17 mA |
| Rated operating voltage |
15 ... 34 VDC |
| Operating current |
200 mA |
| Switching element |
Normally open contact (NO) |
| Protection circuit integrated |
inductive interference protection Protection against polarity reversal Surge protection Max. fuse rating suppressed switch-on fault impulse wire-breakage monitoring Voice transmission protection |
| Switching frequency, approx. |
800 Hz |
Electrical data - Digital Output
| Voltage drop Ud, maximum |
2.5 V |
| Design of control elements |
p-type |
| Current leakage Ir, maximum |
0.01 mA |
Status indication
| Note (Integral System Diagnostics, status ) |
yellow LED |
Language filter
Datasheet
Operating instructions (supplementary sheet/quick guide)
Declaration of conformity (EC)
Download the latest version of Adobe Reader
Product picture (catalogue individual photo)
ID: kifl4f26
| 184.8 kB | .jpg | 79.375 x 263.52500000000003 mm - 225 x 747 px - 72 dpi
| 219.0 kB | .png | 74.083 x 245.88600000000002 mm - 210 x 697 px - 72 dpi
| 39.7 kB | .jpg | 37.042 x 123.47200000000001 mm - 105 x 350 px - 72 dpi
| 26.0 kB | .png | 74.083 x 74.083 mm - 210 x 210 px - 72 dpi
| 19.2 MB | .png | 167.10500000000002 x 553.2860000000001 mm - 2000 x 6622 px - 304 dpi
Dimensional drawing basic component
K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, 42279 Wuppertal
The details and data referred to have been carefully checked. Images may diverge from original. Further technical data can be found in the manual. Technical amendments and errors possible.