IFL 20-400-10/01YKG-1522
IFL 20-400-10/01YKG-1522
Downloads
- Design Ø 40 mm
Ordering data
| Product type description |
IFL 20-400-10/01YKG-1522 |
| Article number (order number) |
101082836 |
| EAN (European Article Number) |
4030661019062 |
| eCl@ss number, version 12.0 |
27-27-40-01 |
| eCl@ss number, version 11.0 |
27-27-01-01 |
| eCl@ss number, version 9.0 |
27-27-01-01 |
| ETIM number, version 7.0 |
EC002714 |
| ETIM number, version 6.0 |
EC002714 |
General data
| Standards |
DIN VDE 0660-208 EN IEC 60947-5-2 |
| Housing construction form |
Cylinder smooth |
| Installation conditions (mechanical) |
not flush |
| Housing material |
Plastic |
| Active area |
Plastic |
| Material of the terminal fixing |
Plastic |
| Gross weight |
170 g |
General data - Features
| Integral system diagnostics, status |
Yes |
Mechanical data - Switching distances
| Nominal switching distance Sn |
20 mm |
| Note (switching distance) |
All switching distances in accordance EN IEC 60947-5-2 |
Mechanical data - Connection technique
| Length of cable |
2 m |
| Termination |
Screw connection |
| Cable section, maximum |
2 x 1.5 mm² |
Mechanical data - Dimensions
| Diameter of sensor |
40 mm |
| Length of sensor |
108 mm |
| Width of sensor |
40 mm |
| Height of sensor |
57 mm |
Ambient conditions
| IP Degree of protection |
IP65 |
| Ambient temperature |
-25 ... +70 °C |
| Resistance to vibrations |
10 … 55 Hz, amplitude 1 mm |
| Restistance to shock |
30 g / 11 ms |
| Protection class |
II |
Ambient conditions - Insulation values
| Rated impulse withstand voltage Uimp |
4 kV |
Electrical data
| Rated supply frequency, minimum |
45 Hz |
| Rated supply frequency, maximum |
65 Hz |
| Operating voltage |
15 ... 250 VAC |
| Type of voltage range |
AC |
| Operating current, minimum |
10 mA |
| Rated operating voltage |
15 ... 250 VAC |
| Operating current |
500 mA |
| Switching element |
NO contact or NC contact |
| Protection circuit integrated |
inductive interference protection Surge protection Max. fuse rating |
| Switching frequency, approx. |
10 Hz |
Electrical data - Digital Output
| Voltage drop Ud, maximum |
7.5 V |
| Current at Voltage drop Ud |
0.15 A |
| Design of control elements |
Two-wire |
| Current leakage Ir, maximum |
1 mA |
Status indication
| Note (Integral System Diagnostics, status ) |
yellow LED |
Scope of delivery
| Note (scope of delivery, number and type) |
Clamp H 40 is included in delivery |
Note
| Note (General) |
Programmable by repositioning the plug-in jumper at the terminal screws |
Language filter
Datasheet
Operating instructions (supplementary sheet/quick guide)
Declaration of conformity (EC)
Download the latest version of Adobe Reader
Product picture (catalogue individual photo)
ID: kifl2f04
| 587.2 kB | .jpg | 352.778 x 529.167 mm - 1000 x 1500 px - 72 dpi
| 48.9 kB | .png | 74.083 x 111.125 mm - 210 x 315 px - 72 dpi
| 36.9 kB | .jpg | 82.197 x 123.47200000000001 mm - 233 x 350 px - 72 dpi
| 38.1 kB | .png | 74.083 x 74.083 mm - 210 x 210 px - 72 dpi
| 5.6 MB | .png | 169.249 x 254 mm - 1999 x 3000 px - 300 dpi
Dimensional drawing basic component
K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, 42279 Wuppertal
The details and data referred to have been carefully checked. Images may diverge from original. Further technical data can be found in the manual. Technical amendments and errors possible.
Generated at: 01/05/2026, 16:49