PS226-Z02-STR-F230
- only for positioning tasks
- thermoplastic enclosure with foldable latching cover
- cable entry 2 x M20 x 1,5
- Design to EN 50047
- LED version available
- Spring rod
Ordering data
| Product type description |
PS226-Z02-STR-F230 |
| Article number (order number) |
103061443 |
| EAN (European Article Number) |
4030661674285 |
| eCl@ss number, version 12.0 |
27-27-06-01 |
| eCl@ss number, version 11.0 |
27-27-06-01 |
| eCl@ss number, version 9.0 |
27-27-06-01 |
| ETIM number, version 7.0 |
EC000030 |
| ETIM number, version 6.0 |
EC000030 |
General data
| Standards |
EN IEC 60947-5-1 |
| Housing material |
Plastic, glass-fibre-reinforced |
General data - Features
| Number of safety contacts |
2 |
Safety classification
| Mission time |
20 Year(s) |
Mechanical data
| Actuating element |
Spring rod lever |
| Mechanical lifetime, minimum |
10,000,000 Operations |
| Positive break force, minimum |
40 N |
| Tightening torque of the fixing screws |
1.2 Nm |
Mechanical data - Connection technique
| Connector position |
Right |
| Termination |
Connector plug M12, 4-pole |
| Tightening torque of electrical connection, minimum |
0.6 Nm |
| Tightening torque of electrical connection, maximum |
0.8 Nm |
Mechanical data - Dimensions
| Length of sensor |
33 mm |
| Width of sensor |
59 mm |
Ambient conditions
| IP Degree of protection |
IP66 IP67 |
| Ambient temperature |
-30 ... +80 °C |
| Protection class |
II |
Ambient conditions - Insulation values
| Rated insulation voltage Ui |
240 V |
| Rated impulse withstand voltage Uimp |
0.8 kV |
| Degree of pollution |
3 |
Electrical data
| Thermal test current |
4 A |
| Required rated short-circuit current |
400 A |
| Utilisation category AC-15 |
50 VAC |
| Utilisation category AC-15 |
3 A |
| Utilisation category DC-13 |
24 VDC |
| Utilisation category DC-13 |
3 A |
| Switching element |
2 NC contact |
| Switching principle |
Snap action |
| Maximale Schalthäufigkeit |
5,000 /h |
| Material of the contacts, electrical |
Silver |
Language filter
Datasheet
Operating instructions and Declaration of conformity
Brochure
SISTEMA-VDMA library
Download the latest version of Adobe Reader
Product picture (catalogue individual photo)
ID: kps2-str-ff01
| 524.1 kB | .jpg | 352.778 x 665.692 mm - 1000 x 1887 px - 72 dpi
| 22.0 kB | .jpg | 65.26400000000001 x 123.47200000000001 mm - 185 x 350 px - 72 dpi
| 17.2 kB | .png | 74.083 x 74.083 mm - 210 x 210 px - 72 dpi
| 56.9 kB | .png | 74.083 x 139.70000000000002 mm - 210 x 396 px - 72 dpi
| 4.8 MB | .png | 169.333 x 319.617 mm - 2000 x 3775 px - 300 dpi
Dimensional drawing basic component
Dimensional drawing actuator
Diagram
Contact arrangement
Schmersal, Inc., 15 Skyline Drive, NY 10532 Hawthorne
The details and data referred to have been carefully checked. Images may diverge from original. Further technical data can be found in the manual. Technical amendments and errors possible.
Generated at: 5/2/2026, 11:48 AM