M3R 330-11Y-M20
- Metal enclosure
- Long life
- 40 mm x 76 mm x 40 mm ( basic component)
- Suitable for low actuating speeds
- 1 Cable entry M 20 x 1.5
- free of silicon
- proved in power station applications
- Actuator heads can be repositioned by 4 x 90°
- with bellows to protect against heavy soiling
Ordering data
| Note (Delivery capacity) |
Not available! |
| Product type description |
M3R 330-11Y-M20 |
| Article number (order number) |
101161735 |
| EAN (European Article Number) |
4030661196855 |
| eCl@ss number, version 12.0 |
27-27-06-01 |
| eCl@ss number, version 11.0 |
27-27-06-01 |
| eCl@ss number, version 9.0 |
27-27-06-01 |
| ETIM number, version 7.0 |
EC000030 |
| ETIM number, version 6.0 |
EC000030 |
Approvals - Standards
| Certificates |
cULus CCC |
General data
| Standards |
EN IEC 60947-5-1 |
| Working principle |
mechanical |
| Slide form |
Castor |
| Housing material |
Light-alloy diecast, paint finish |
| Housing coating material |
painted |
| Gross weight |
245 g |
General data - Features
| Number of normally closed (NC) |
1 |
| Number of normally open (NO) |
1 |
Mechanical data
| Actuating element |
Roller plunger |
| Roller material |
Plastic |
| Mechanical lifetime, minimum |
30,000,000 Operations |
| Actuating force, minimum |
17 N |
| Contact opening |
2 x 0.5 mm |
| Actuating speed, minimum |
1 mm/min |
| Repeat accuracy of switching points |
0.02 mm |
Mechanical data - Connection technique
| Termination |
Screw terminals M20 x 1.5 |
| Cable section, minimum |
1.5 mm² |
| Cable section, maximum |
2.5 mm² |
| Note |
All indications including the conductor ferrules. |
| Wire cross-section |
13 AWG |
Mechanical data - Dimensions
| Length of sensor |
40 mm |
| Width of sensor |
75.3 mm |
| Height of sensor |
103.5 mm |
| Width of Castor |
4.6 mm |
Ambient conditions
| IP Degree of protection |
IP65 |
| Ambient temperature |
-30 ... +90 °C |
| Restistance to shock |
50 g / 6 ms |
Ambient conditions - Insulation values
| Rated insulation voltage Ui |
500 V |
| Rated impulse withstand voltage Uimp |
4 kV |
Electrical data
| Thermal test current |
6 A |
| Utilisation category AC-15 |
230 VAC |
| Utilisation category AC-15 |
2.5 A |
| Switching element |
1 NO contact, 1 NC contacts |
| Note (Switching element) |
galvanically separated contact bridges |
| Switching principle |
Snap action |
| Bounce duration, maximum |
1.5 ms |
| Switchover time, maximum |
10 ms |
| Material of the contacts, electrical |
Silver |
Language filter
Datasheet
Operating instructions (supplementary sheet/quick guide)
UL Certificate
Declaration of conformity (EC)
Download the latest version of Adobe Reader
Product picture (catalogue individual photo)
ID: km330f10
| 895.0 kB | .jpg | 352.778 x 489.656 mm - 1000 x 1388 px - 72 dpi
| 81.9 kB | .png | 74.083 x 102.658 mm - 210 x 291 px - 72 dpi
| 41.6 kB | .png | 74.083 x 74.083 mm - 210 x 210 px - 72 dpi
| 7.3 MB | .png | 166.55700000000002 x 231.26500000000001 mm - 2000 x 2777 px - 305 dpi
| 59.6 kB | .jpg | 88.9 x 123.47200000000001 mm - 252 x 350 px - 72 dpi
Dimensional drawing basic component
Dimensional drawing actuator
Switch travel diagram
Diagram
131161735 M3R 330-11Y-M20
- Metal enclosure
- Long life
- 40 mm x 76 mm x 40 mm ( basic component)
- Suitable for low actuating speeds
- 1 Cable entry M 20 x 1.5
- free of silicon
- proved in power station applications
- Actuator heads can be repositioned by 4 x 90°
- with bellows to protect against heavy soiling
Schmersal, Inc., 15 Skyline Drive, NY 10532 Hawthorne
The details and data referred to have been carefully checked. Images may diverge from original. Further technical data can be found in the manual. Technical amendments and errors possible.
Generated at: 4/28/2026, 8:33 AM