BNS 16 ST3-AS D
| Product type description: BNS 16(1)-AS (2) |
| (1) | |
| ST1 | Bottom-side connector |
| ST2 | Connector at the right-hand side |
| ST3 | Connector at the left-hand side |
| (2) | |
| V | Actuation front side |
| D | Actuation cover-side |
- connector plug M12, left, 4-pole
- Safety sensor
- Thermoplastic enclosure
- no mechanical wear
- 40 mm x 90 mm x 39 mm
- Integrated AS-Interface
- Concealed mounting possible
- Long life
- Insensitive to transverse misalignment
- Insensitive to soiling
- AS-Interface LED and status display
Ordering data
| Product type description |
BNS 16 ST3-AS D |
| Article number (order number) |
101178190 |
| EAN (European Article Number) |
4030661310091 |
| eCl@ss number, version 12.0 |
27-27-44-01 |
| eCl@ss number, version 11.0 |
27-27-24-02 |
| eCl@ss number, version 9.0 |
27-27-24-02 |
| ETIM number, version 7.0 |
EC002544 |
| ETIM number, version 6.0 |
EC002544 |
Approvals - Standards
| Certificates |
cULus ASi-SaW |
General data
| Standards |
EN IEC 62026-2 EN ISO 13849-1 EN IEC 60947-5-3 EN IEC 61508 |
| Working principle |
Magnetic drive |
| Installation conditions (mechanical) |
quasi-flush |
| Housing material |
Glass-fibre, reinforced thermoplastic |
| Reaction time, maximum |
100 ms |
| Gross weight |
145 g |
General data - Features
| Coding |
Yes |
| Integral system diagnostics, status |
Yes |
Safety classification
| Standards |
EN IEC 61508 |
| Performance Level, up to |
e |
| Category |
4 |
| PFH value |
7.42 x 10⁻⁹ /h |
| Note (PFH-value) |
up to max. 500,000 switching cycles/year |
| Safety Integrity Level (SIL), suitable for applications in |
3 |
| Mission time |
20 Year(s) |
Mechanical data
| Active area |
cover-side |
| Actuating element |
Magnet |
| Direction of motion |
Head-on to the active surface |
Mechanical data - Switching distances
| Assured switching distance "ON" Sao |
8 mm |
| Assured switching distance "OFF" Sar |
18 mm |
| Note (switching distance) |
All switching distances in accordance EN IEC 60947-5-3 |
| Note (Repeat accuracy R) |
Repeat accuracy R ≤ 0,1 x Sao |
Mechanical data - Connection technique
| Connector position |
Left |
| Termination |
Connector plug M12, 4-pole, (A-coding) |
Mechanical data - Dimensions
| Length of sensor |
38.5 mm |
| Width of sensor |
40 mm |
| Height of sensor |
90 mm |
Ambient conditions
| Degree of protection |
IP67 |
| Ambient temperature |
-25 ... +60 °C |
| Storage and transport temperature |
-25 ... +70 °C |
| Resistance to vibrations |
10 … 55 Hz, amplitude 1 mm |
| Restistance to shock |
30 g / 11 ms |
| Protection class |
II |
Ambient conditions - Insulation values
| Rated insulation voltage Ui |
32 VDC |
| Rated impulse withstand voltage Uimp |
0.8 kV |
| Overvoltage category |
III |
| Degree of pollution |
3 |
Electrical data - AS Interface
| Rated operating voltage |
18 ... 31.6 VDC (Protection against polarity reversal) |
| AS-i Current consumption, maximum |
50 mA |
Electrical data - AS-Interface specification
| AS-i Specification |
Safety-Slave |
| AS-i Version |
V 2.1 |
| AS-i Profile |
S-0.B.F.E |
| AS-i, IO-Code |
0x0 |
| AS-i, ID-Code |
0xB |
| AS-i, ID-Code1 |
0xF |
| AS-i, ID-Code2 |
0xE |
| AS-i Input, Channel 1 |
Data bits DI 0 / DI 1 = dynamic code transmission |
| AS-i Input, Channel 2 |
Data bits DI 2 / DI 3 = dynamic code transmission |
| AS-i Outputs, DO 0 … DO 3 |
No Function |
| AS-i Parameter bits, P0 ... P3 |
No function |
| Note (AS-i Parameter bits) |
Set the parameter outputs to "1111" (0xF) FID: periphery error |
| AS-i Input module address |
0 |
| Note (AS-i Input module address) |
Preset to address 0, can be changed through AS-interface bus master or hand-held programming device |
Status indication
| Note (LED switching conditions display) |
(1) LED yellow: Channel 1 / AS-i SaW Bit 0.1 (2) LED green/red (AS-i duo LED): Supply voltage / communication error / slave address = 0 / periphery error detected (3) LED yellow: Channel 2 / AS-i SaW Bit 2.3 |
Pin assignment
| PIN 1 |
AS-i + |
| PIN 2 |
n.c. |
| PIN 3 |
AS-Interface - |
| PIN 4 |
n.c. |
Scope of delivery
| Scope of delivery |
Actuator must be ordered separately. |
Accessory
| Recommendation (actuator) |
BPS 16 |
Language filter
Datasheet
Operating instructions and Declaration of conformity
UL Certificate
AS interface safety at work certificate
SISTEMA-VDMA library
Download the latest version of Adobe Reader
Product picture (catalogue individual photo)
ID: kbns1f08
| 738.2 kB | .jpg | 352.778 x 513.292 mm - 1000 x 1455 px - 72 dpi
| 87.2 kB | .png | 74.083 x 107.59700000000001 mm - 210 x 305 px - 72 dpi
| 41.5 kB | .png | 74.083 x 74.083 mm - 210 x 210 px - 72 dpi
| 7.0 MB | .png | 169.249 x 246.38 mm - 1999 x 2910 px - 300 dpi
| 47.4 kB | .jpg | 84.667 x 123.47200000000001 mm - 240 x 350 px - 72 dpi
Dimensional drawing basic component
Dimensional drawing miscellaneous
Operating principle
Contact arrangement
Schmersal, Inc., 15 Skyline Drive, NY 10532 Hawthorne
The details and data referred to have been carefully checked. Images may diverge from original. Further technical data can be found in the manual. Technical amendments and errors possible.
Generated at: 4/18/2026, 2:42 PM