AZ300-ST-SD2P
- Universal coding with RFID technology
- Connector M12, 8-pole
- serial diagnostic output
- Suitable for mounting to profile systems
- Thermoplastic enclosure
- RFID-technology for needs-based protection against tampering
- 3 different directions of actuation
- Compact design
- 3 LEDs to show operating conditions
- Suitable for hinged and sliding guards
- Series-wiring
Ordering data
| Product type description |
AZ300-ST-SD2P |
| Article number (order number) |
103001463 |
| EAN (European Article Number) |
4030661435879 |
| eCl@ss number, version 12.0 |
27-27-26-02 |
| eCl@ss number, version 11.0 |
27-27-26-02 |
| eCl@ss number, version 9.0 |
27-27-26-02 |
| ETIM number, version 7.0 |
EC002592 |
| ETIM number, version 6.0 |
EC002592 |
Approvals - Standards
| Certificates |
TÜV cULus IC |
General data
| Standards |
EN ISO 13849-1 EN IEC 60947-5-1 EN IEC 60947-5-3 EN IEC 61508 |
| Coding |
Universal coding |
| Coding level according to EN ISO 14119 |
Low |
| Working principle |
RFID |
| Housing material |
Glass-fibre, reinforced thermoplastic |
| Reaction time, maximum |
100 ms |
| Duration of risk, maximum |
200 ms |
General data - Features
| Actuator monitored |
Yes |
| Serial diagnostics |
Yes |
| Latching |
Yes |
| Short circuit detection |
Yes |
| Cross-circuit detection |
Yes |
| Series-wiring |
Yes |
| Safety functions |
Yes |
| Integral system diagnostics, status |
Yes |
| Number of safety contacts |
2 |
Safety classification
| Standards |
EN IEC 61508 |
| Performance Level, up to |
e |
| Category |
4 |
| PFH value |
5.20 x 10⁻¹⁰ /h |
| Safety Integrity Level (SIL), suitable for applications in |
3 |
| Mission time |
20 Year(s) |
Mechanical data
| Mechanical lifetime, minimum |
1,000,000 Operations |
| Note (Mechanical lifetime) |
> 50,000 operations for door weights ≤ 5 kg Actuating speed ≤ 0.5 m/s |
| Latching force, adjustable, position 1 |
25 N |
| Latching force, adjustable, position 2 |
50 N |
Mechanical data - Switching distances
| Switch distance, typical |
2 mm |
| Assured switching distance "ON" Sao |
1 mm |
| Assured switching distance "OFF" Sar |
20 mm |
| Note (switching distance) |
All switching distances in accordance EN IEC 60947-5-3 |
Mechanical data - Connection technique
| Note (length of the sensor chain) |
Cable length and cross-section change the voltage drop dependiing on the output current |
| Note (series-wiring) |
Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD |
| Termination |
Connector M12, 8-pole, A-coded |
Mechanical data - Dimensions
| Length of sensor |
35 mm |
| Width of sensor |
85 mm |
| Height of sensor |
100 mm |
Ambient conditions
| Degree of protection |
IP66 IP67 IP69K |
| Ambient temperature |
+0 ... +60 °C |
| Storage and transport temperature |
-10 ... +90 °C |
| Resistance to vibrations |
10 … 150 Hz, amplitude 0.35 mm |
| Restistance to shock |
30 g / 11 ms |
| Protection class |
II |
Ambient conditions - Insulation values
| Rated insulation voltage Ui |
32 VDC |
| Rated impulse withstand voltage Uimp |
0.8 kV |
| Overvoltage category |
III |
| Degree of pollution |
3 |
Electrical data
| Current consumption at 24V |
5 mA |
| No-load supply current I0, typical |
100 mA |
| Operating current |
50 mA |
| Required rated short-circuit current |
100 A |
| Inputs, Switching thresholds |
−3 V … 5 V (Low) 15 V … 30 V (High) |
| Time to readiness, maximum |
5,000 ms |
| Switching frequency, approx. |
0.5 Hz |
| Electrical fuse rating, maximum |
2 A |
Electrical data - Safety digital inputs
| Switching thresholds |
−3 V … 5 V (Low) 15 V … 30 V (High) |
| Current consumption at 24 V |
5 mA |
Electrical data - Safety digital outputs
| Rated operating current (safety outputs) |
250 mA |
| Design of control elements |
short-circuit proof, p-type |
| Voltage drop Ud, maximum |
4 V |
| Leakage current Ir, maximum |
0.5 mA |
| Voltage, Utilisation category DC-13 |
24 VDC |
| Current, Utilisation category DC-13 |
0.25 A |
Electrical data - Diagnostic outputs
| Design of control elements |
short-circuit proof, p-type |
| Voltage drop Ud, maximum |
4 V |
| Voltage, Utilisation category DC-13 |
24 VDC |
| Current, Utilisation category DC-13 |
0.05 A |
Electrical data - Serial diagnostic SD
| Designation, Serial diagnostic SD |
OUT |
| Operation current |
150 mA |
| Design of control elements |
short-circuit proof, p-type |
| Wiring capacitance |
50 nF |
Status indication
| Note (LED switching conditions display) |
Operating condition: LED green Error / functional defect: LED red Supply voltage UB: LED green |
Pin assignment
| PIN 1 |
A1 Supply voltage UB |
| PIN 2 |
X1 Safety input 1 |
| PIN 3 |
A2 GND |
| PIN 4 |
Y1 Safety output 1 |
| PIN 5 |
OUT serial diagnostic output |
| PIN 6 |
X2 Safety input 2 |
| PIN 7 |
Y2 Safety output 2 |
| PIN 8 |
n.c. |
Scope of delivery
| Scope of delivery |
Actuator must be ordered separately. |
| Scope of delivery of mounting material |
2 x M6 |
Accessory
| Recommendation (actuator) |
AZ/AZM300-B1 |
Note
| Note (General) |
For doors that are flush with the door frame, the optional mounting plate MP-AZ/AZM300-1 can be used. For glass and Makrolon doors, the optional mounting kit MS-AZ/AZM300-B1-1 can be used. |
Language filter
Datasheet
Operating instructions and Declaration of conformity
Declaration of conformity (EC)
UL Certificate
BG-test certificate
SISTEMA-VDMA library
Download the latest version of Adobe Reader
Product picture (catalogue individual photo)
ID: kazm3f26
| 905.6 kB | .jpg | 352.425 x 440.619 mm - 999 x 1249 px - 72 dpi
| 59.1 kB | .png | 74.083 x 92.42800000000001 mm - 210 x 262 px - 72 dpi
| 59.4 kB | .jpg | 98.778 x 123.47200000000001 mm - 280 x 350 px - 72 dpi
| 46.4 kB | .png | 74.083 x 74.083 mm - 210 x 210 px - 72 dpi
| 7.4 MB | .png | 169.333 x 211.58200000000002 mm - 2000 x 2499 px - 300 dpi
Dimensional drawing basic component
Dimensional drawing miscellaneous
Contact arrangement
Wiring example
Schmersal, Inc., 15 Skyline Drive, NY 10532 Hawthorne
The details and data referred to have been carefully checked. Images may diverge from original. Further technical data can be found in the manual. Technical amendments and errors possible.