SFB-EC-8M12-IOP
- Safety fieldbox for EtherCAT with FSoE
- For connection of up to 8 safety switching devices
- Integrated dual-port switch
- Protection class IP66, IP67
- ctrlX World compatible!
Ordering data
| Product type description |
SFB-EC-8M12-IOP |
| Article number (order number) |
103047531 |
| EAN (European Article Number) |
4030661628707 |
| eCl@ss number, version 12.0 |
27-24-26-04 |
| eCl@ss number, version 11.0 |
27-24-26-04 |
| eCl@ss number, version 9.0 |
27-24-26-04 |
| ETIM number, version 7.0 |
EC001599 |
| ETIM number, version 6.0 |
EC001599 |
| Notice |
ctrlX World compatible! |
Approvals - Standards
| Certificates |
TÜV cULus UKCA |
General data
| Standards |
EN IEC 61131-1 EN IEC 61131-2 EN ISO 13849-1 EN IEC 60947-5-3 EN IEC 61508 |
| Housing material |
Thermoplastic, Polyamide PA 6 GF |
| Material of the marking plate |
Plastic, Polyamide PA |
| Material of viewing window |
Polyamide PACM 12 |
| Material of electronic encapsulation |
Polyurethane 2K PU |
| Gross weight |
597 g |
General data - Features
| Integral system diagnostics, general |
Yes |
Safety classification
| Standards |
EN ISO 13849-1 EN IEC 61508 |
Safety classification - Safety inputs 2-channels
| Performance Level, up to |
e |
| Category |
4 |
| Diagnostic Coverage (DC) Level |
99 % |
| PFH value |
1.10 x 10⁻⁹ /h |
| PFDavg |
9.60 x 10⁻⁵ |
| Safety Integrity Level (SIL), suitable for applications in |
3 |
| Mission time |
20 Year(s) |
| Response time of local safety input ⇒ Fieldbus, maximum |
30 ms |
| Notice |
The SFB fulfils the requirements as PDDB (proximity switch with defined behaviour under fault conditions) according to EN 60947-5-3 in combination with magnetic sensors (2 NC contacts) up to PL e / SIL 3. |
Safety classification - Safety inputs 1-channel
| Performance Level, up to |
d |
| Category |
2 |
| Diagnostic Coverage (DC) Level |
90 % |
| PFH value |
2.30 x 10⁻⁷ /h |
| PFDavg |
2.00 x 10⁻² |
| Safety Integrity Level (SIL), suitable for applications in |
1 |
| Mission time |
20 Year(s) |
| Response time of local safety input > Fieldbus, maximum |
30 ms |
| Test interval for error detection |
10 s |
Safety classification - Safety outputs 1-channel
| Performance Level, up to |
d |
| Category |
3 |
| Diagnostic Coverage (DC) Level |
90 % |
| PFH value |
1.00 x 10⁻⁷ /h |
| PFDavg |
8.80 x 10⁻³ |
| Safety Integrity Level (SIL), suitable for applications in |
2 |
| Mission time |
20 Year(s) |
| Reaction time Fieldbus > local safety output |
50 ms |
Safety classification - Safety outputs 2-channels
| Performance Level, up to |
e |
| Category |
4 |
| Diagnostic Coverage (DC) Level |
99 % |
| PFH value |
1.20 x 10⁻⁹ /h |
| PFDavg |
1.10 x 10⁻⁴ |
| Safety Integrity Level (SIL), suitable for applications in |
3 |
| Mission time |
20 Year(s) |
| Reaction time Fieldbus > local safety output |
50 ms |
Mechanical data
| Mounting |
Screws |
| Type of the fixing screws |
2x M6 |
| Tightening torque of the fixing screws, maximum |
3 Nm |
| Type of the fixing screws, viewing window |
2x TX10 (Torx) |
| Tightening torque of the fastening screws for the viewing window, maximum |
0.6 Nm |
Mechanical data - Connection technique
| Termination |
M12 Connector socket/connector |
| Terminal connector, Input/Output |
X0 - X7: M12, 8-pole, A-coded |
| Terminal Connector, Power I/O |
M12 POWER, 4-pole, T-coded |
| Terminal Connector, Field bus |
M12, 4-pole, D-coded |
| Tightening torque of electrical connection, minimum |
0.8 Nm |
| Tightening torque of electrical connection, maximum |
1.5 Nm |
Mechanical data - Dimensions
| Length |
222.8 mm |
| Width |
63 mm |
| Height |
36.1 mm |
Ambient conditions
| Degree of protection |
IP66 IP67 |
| Ambient temperature |
-25 ... +55 °C |
| Storage and transport temperature |
-25 ... +70 °C |
| Relative humidity, minimum |
10 % |
| Relative humidity, maximum |
95 % |
| Note (Relative humidity) |
non-condensing |
| Resistance to vibrations |
10 … 150 Hz, amplitude 0.35 mm / 5 g |
| Restistance to shock |
30 g / 11 ms |
| Protection class |
III |
| Permissible installation altitude above sea level, maximum |
2,000 m |
Ambient conditions - Insulation values
| Rated insulation voltage Ui |
32 VDC |
| Rated impulse withstand voltage Uimp |
0.8 kV |
| Overvoltage category |
III |
| Degree of pollution |
3 |
Electrical data
| Operating voltage |
24 VDC -15 % / +10 % (stabilised PELV power supply) |
| Current consumption |
200 mA |
| Rated operating voltage |
24 VDC |
| Operating current |
10,000 mA |
| Note (Electrical data, Fuse rating) |
External fuse protection required ≤ 10A slow blow when used to UL 61010. |
| Time to readiness, maximum |
12,000 ms |
| Device Watchdog Time |
12 ms |
| Device Acknowledgement Time, maximum |
25 ms |
| Reaction Time Safety Input, maximum |
30 ms |
| Reaction Time Safety Output, maximum |
50 ms |
Electrical data - Communication protocols
| Feldbus Protokoll |
EtherCAT / FSoE |
| Fieldbus specification |
V1.0.10 |
| Specification safety fieldbus |
V1.2.0 |
| Transfer rate |
100 Mbit/s Full Duplex |
| Adressing |
Topology dependent |
| Integrated switch |
Dual Port, 100 Mbit/s |
| Service interface |
WEB-Interface HTTP |
Electrical data - Device Ports
| Bezeichnung, Geräteanschlüsse |
X0 ... X7 |
| Cable length, device port |
30 m |
Electrical data - Power supply external devices
| Designation, Power supply |
A1 and A2 |
| Rated operating voltage |
24 VDC |
| Rated operating current |
800 mA |
| Internal electrical fuse |
1.5 A (Integrated automatic resettable fuse) |
Electrical data - Safety digital inputs
| Designation, Safety inputs |
X1 and X2 |
| Switching thresholds |
−3 V … 5 V (Low) 13 V ... 30 V (High) |
| Current consumption at 24 V |
6 mA |
| Permissible residual drive current |
1 mA |
| Test pulse duration, minimum |
0.01 ms |
| Test pulse duration, maximum |
1 ms |
| Test pulse interval, minimum |
20 ms |
| Test pulse interval, maximum |
120,000 ms |
| Classification ZVEI CB24I, Sink |
C1 |
| Classification ZVEI CB24I, Source |
C1 C2 C3 |
Electrical data - Safety digital outputs
| Designation, Safety outputs |
DO |
| Design of control elements |
short-circuit proof, p-type |
| Voltage drop Ud, maximum |
2 V |
| Leakage current Ir, maximum |
0.5 mA |
| Voltage, Utilisation category DC-12 |
24 VDC |
| Current, Utilisation category DC-12 |
0.8 A |
| Voltage, Utilisation category DC-13 |
24 VDC |
| Current, Utilisation category DC-13 |
0.8 A |
| Note, Utilisation category DC-13 |
Inductive load, maximum 400 mH |
| Switching frequency, maximum |
1 Hz |
| Test pulse duration, maximum |
1 ms |
| Test pulse interval, minimum |
15 ms |
| Test pulse interval, maximum |
500 ms |
| Classification ZVEI CB24I, Source |
C1 |
| Classification ZVEI CB24I, Sink |
C1 |
Electrical data - Diagnostic inputs / FB-Interface
| Designation, Diagnostic inputs / FB-Interface |
DI |
| Switching thresholds |
−3 V … 5 V (Low) 15 V … 30 V (High) |
| Current consumption at 24V |
12 mA |
| Input debounce filter |
10 ms |
| Data transfer rate FB-Interface |
19,2 kBaud |
Electrical data - Test pulse output
| Designation, Test pulse outputs |
Y1 and Y2 |
| Design of control elements |
short-circuit proof, p-type |
| Voltage drop Ud, maximum |
1 V |
| Current leakage Ir, maximum |
0.5 mA |
| Voltage, Utilisation category DC-12 |
24 VDC |
| Y1 rated current at 24 V |
15 mA |
| Y2 rated current at 24 V |
10 mA |
| Y2 rated current at 0 V |
30 mA |
| Test pulse interval, typical |
500 ms |
| Test pulse duration, maximum |
1 ms |
| Classification ZVEI CB24I, Sink |
C1 |
| Classification ZVEI CB24I, Source |
C1 |
LED status display - LED 01
| LED status |
Error LED device port |
| LED position |
E: 0 ... 7 |
| LED colour |
green/red |
LED status display - LED 02
| LED status |
Input LED device port |
| LED position |
I: 0 ... 7 |
| LED colour |
Yellow |
LED status display - LED 03
| LED status |
Link / Activity-LED Ethernet Port |
| LED position |
L / A: IN + OUT |
| LED colour |
Green |
LED status display - LED 05
| LED status |
EtherCAT RUN LED |
| LED position |
"RUN": Module |
| LED colour |
Green |
LED status display - LED 06
| LED status |
EtherCAT error LED |
| LED position |
"ERR": Module |
| LED colour |
Red |
LED status display - LED 07
| LED status |
Fieldbox Diag-LED |
| LED position |
"Diag": Module |
| LED colour |
green/red |
LED status display - LED 08
| LED status |
Power-LED fieldbox |
| LED position |
"Pwr": Module |
| LED colour |
Green |
Other data
| Note (applications) |
Safe field box with decentralised I/Os |
Language filter
Datasheet
Operating instructions and Declaration of conformity
System Manual
Getting Started
BG-test certificate
UL Certificate
UKCA certificate
Device description files
General information
Brochure
SISTEMA-VDMA library
Download the latest version of Adobe Reader
Product picture (catalogue individual photo)
ID: ksfb-ec-f04
| 89.9 MB | .tif | 381 x 560.493 mm - 4500 x 6620 px - 300 dpi
| 480.5 kB | .jpg | 359.833 x 529.167 mm - 1020 x 1500 px - 72 dpi
| 70.0 kB | .png | 74.083 x 109.00800000000001 mm - 210 x 309 px - 72 dpi
| 51.2 kB | .jpg | 83.961 x 123.47200000000001 mm - 238 x 350 px - 72 dpi
| 33.6 kB | .png | 74.083 x 74.083 mm - 210 x 210 px - 72 dpi
| 5.9 MB | .png | 169.333 x 249.089 mm - 2000 x 2942 px - 300 dpi
K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, 42279 Wuppertal
The details and data referred to have been carefully checked. Images may diverge from original. Further technical data can be found in the manual. Technical amendments and errors possible.
Generated at: 17/04/2026, 18:22