US 432Y-M20
| Product type description: U(1) 432Y-(2)-(3) |
| (1) | |
| S | Plunger S |
| K | Offset roller lever K |
| 8H | Roller lever 8H |
| H | Roller lever H |
| 3H | Roller lever 3H |
| 7H | Roller lever 7H |
| 4H | Spring rod lever on shaft 4H |
| 9H | Rod lever 9H |
| 10H | Rod lever 10H |
| 2H | Leaf spring lever 2H |
| 6H | Leaf spring lever 6H |
| (2) | |
| without | 2 NC contact |
| 2S | 2 NO contacts |
| 1S/1OE | 1 NO contact/1 NC contact |
| (3) | |
| 1272 | Version for low temperatures to -30 °C |
- Metal enclosure
- 2 Contacts
- 62 mm x 80 mm x 50 mm ( basic component)
- Switching points and contact function adjustable
- 3 cable entries M 20 x 1.5
Ordering data
| Product type description |
US 432Y-M20 |
| Article number (order number) |
101176036 |
| EAN (European Article Number) |
4030661306346 |
| eCl@ss number, version 12.0 |
27-27-06-01 |
| eCl@ss number, version 11.0 |
27-27-06-01 |
| eCl@ss number, version 9.0 |
27-27-06-01 |
| ETIM number, version 7.0 |
EC000030 |
| ETIM number, version 6.0 |
EC000030 |
Approvals - Standards
| Certificates |
cULus |
General data
| Standards |
EN IEC 60947-5-1 |
| Working principle |
mechanical |
| Slide form |
Sphere |
| Housing material |
Light alloy die-casting |
| Housing coating material |
painted |
| Gross weight |
310 g |
General data - Features
| Number of normally closed (NC) |
2 |
Safety classification - Safety outputs
| B10D Normally-closed contact (NC) |
2,000,000 Operations |
Mechanical data
| Actuating element |
Plunger |
| Mechanical lifetime, minimum |
10,000,000 Operations |
| Actuating angle |
20 ° |
| Contact opening |
2 x 1.5 mm |
| Actuating speed, minimum |
1 mm/min |
| Actuating speed, maximum |
1 m/s |
| Note (Actuating speed) |
Actuating speed with vertical actuating angle to switch axis |
Mechanical data - Connection technique
| Termination |
Screw terminals M20 x 1.5 |
| Cable section, minimum |
1.5 mm² |
| Cable section, maximum |
2.5 mm² |
| Note |
All indications including the conductor ferrules. |
| Wire cross-section |
13 AWG |
Mechanical data - Dimensions
| Length of sensor |
50 mm |
| Width of sensor |
62 mm |
| Height of sensor |
91 mm |
| Diameter of the Plunger |
6 mm |
Ambient conditions
| Degree of protection |
IP65 |
| Ambient temperature |
-20 ... +60 °C |
Ambient conditions - Insulation values
| Rated insulation voltage Ui |
500 V |
Electrical data
| Thermal test current |
16 A |
| Switching element |
Opener (NC) |
| Switching principle |
Slow action |
| Material of the contacts, electrical |
Silver |
Note
| Note (General) |
Type of contact and switching points can be factory set to order. Actuation from the side of the plunger should be avoided, since this reduces the mechanical life of the position switch. |
Language filter
Datasheet
Operating instructions (supplementary sheet/quick guide)
Declaration of conformity (EC)
UL Certificate
Download the latest version of Adobe Reader
Product picture (catalogue individual photo)
ID: ku43sf01
| 695.2 kB | .jpg | 352.778 x 439.91400000000004 mm - 1000 x 1247 px - 72 dpi
| 80.0 kB | .png | 73.73100000000001 x 92.075 mm - 209 x 261 px - 72 dpi
| 51.2 kB | .png | 74.083 x 74.083 mm - 210 x 210 px - 72 dpi
| 7.5 MB | .png | 169.333 x 211.15900000000002 mm - 2000 x 2494 px - 300 dpi
| 51.8 kB | .jpg | 99.131 x 123.47200000000001 mm - 281 x 350 px - 72 dpi
Dimensional drawing basic component
Dimensional drawing actuator
Switch travel diagram
Diagram