IFOD 10-30-10/01P
| Product type description: IFOD (1)-(2)-(3)(4) |
| (1) | |
| 8 | Switching distance 800 mm |
| 10 | Switching distance 1000 mm |
| (2) | |
| 30 | Cylinder, thread M30, metal |
| 300 | Cylinder, thread M30, plastic |
| (3) | |
| 01 | Opener (NC) |
| 10 | Normally open contact (NO) |
| 10/01 | NO contact / NC contact with wiring compartment |
| 11 | 1 NO contact / 1 NC contact antivalent |
| (4) | |
| without | Design of control output Two-wire |
| P | p-type |
- Metal enclosure
- DC 3-wire
- Wiring compartment can be turned 180°
- Design M30
- Wiring compartment
Ordering data
| Product type description |
IFOD 10-30-10/01P |
| Article number (order number) |
103038716 |
| EAN (European Article Number) |
4030661545974 |
| eCl@ss number, version 12.0 |
27-27-09-03 |
| eCl@ss number, version 11.0 |
27-27-09-03 |
| eCl@ss number, version 9.0 |
27-27-09-03 |
| ETIM number, version 7.0 |
EC001821 |
| ETIM number, version 6.0 |
EC001821 |
General data
| Standards |
DIN VDE 0660-208 EN IEC 60947-5-2 |
| Housing construction form |
Cylinder, thread |
| Housing material |
Brass |
| Housing coating material |
nickel-plated |
| Active area |
Plastic |
| Material of the nuts |
Brass |
| Detection range Sd, maximum |
1,000 mm |
| Gross weight |
148 g |
General data - Features
| Integral system diagnostics, status |
Yes |
| Number of cable wires |
3 |
Mechanical data
| Tightening torque of nuts, maximum |
30 Nm |
Mechanical data - Connection technique
| Termination |
Screw connection |
| Cable section, maximum |
3 x 1.5 mm² |
| Wire cross-section |
15 AWG |
Mechanical data - Dimensions
| ISO thread of the sensor |
M30 |
| width across flats |
36 BK |
| Length of sensor |
118 mm |
| Width of sensor |
46 mm |
| Height of sensor |
46 mm |
Ambient conditions
| Degree of protection |
IP65 |
| Ambient temperature |
-5 ... +70 °C |
| Protection class |
II |
Electrical data
| Operating voltage |
15 ... 60 VDC |
| Type of voltage range |
DC |
| No-load supply current I0, typical |
2.4 mA |
| Rated operating voltage |
15 ... 60 VDC |
| Operating current |
400 mA |
| Switching element |
NO contact or NC contact |
| Protection circuit integrated |
inductive interference protection |
| Switching frequency, approx. |
100 Hz |
Electrical data - Digital Output
| Voltage drop Ud, maximum |
2 V |
| Current at Voltage drop Ud |
0.4 A |
| Design of control elements |
p-type |
Status indication
| Note (Integral System Diagnostics, status ) |
yellow LED |
Language filter
Datasheet
Operating instructions and Declaration of conformity
Declaration of conformity (EC)
Download the latest version of Adobe Reader
Product picture (catalogue individual photo)
ID: kifo8f02
| 425.2 kB | .jpg | 352.778 x 529.167 mm - 1000 x 1500 px - 72 dpi
| 67.4 kB | .png | 74.083 x 111.125 mm - 210 x 315 px - 72 dpi
| 30.5 kB | .png | 74.083 x 74.083 mm - 210 x 210 px - 72 dpi
| 4.7 MB | .png | 169.249 x 254 mm - 1999 x 3000 px - 300 dpi
| 35.3 kB | .jpg | 82.197 x 123.47200000000001 mm - 233 x 350 px - 72 dpi
Schmersal Ltd., Sparrowhawk Close, WR14 1GL Malvern
The details and data referred to have been carefully checked. Images may diverge from original. Further technical data can be found in the manual. Technical amendments and errors possible.
Generated at: 15/04/2026, 06:21