AZM190-11/01RKAT-24VDC
AZM190-11/01RKAT-24VDC
- Thermoplastic enclosure
- Long life
- Interlock with protection against incorrect locking.
- 89 mm x 178 mm x 41 mm
- Actuating head can be repositioned by 4 x 90°
- 2 cable entries M 20 x 1.5
- Wiring compartment
- Slim design, particularly suitable for fitting on hinged doors, aluminium profiles and fencing
- Sealing mechanism to prevent the ingress of dirt
- Cut clamp termination
Ordering data
| Product type description |
AZM190-11/01RKAT-24VDC |
| Article number (order number) |
103034469 |
| EAN (European Article Number) |
4030661535494 |
| eCl@ss number, version 12.0 |
27-27-26-03 |
| eCl@ss number, version 11.0 |
27-27-26-03 |
| eCl@ss number, version 9.0 |
27-27-26-03 |
| ETIM number, version 7.0 |
EC002593 |
| ETIM number, version 6.0 |
EC002593 |
Approvals - Standards
| Certificates |
cULus |
General data
| Standards |
BG-GS-ET-19 EN ISO 13849-1 EN ISO 14119 EN IEC 60947-5-1 |
| Coding level according to EN ISO 14119 |
Low |
| Working principle |
electromechanical |
| Housing material |
Glass-fibre, reinforced thermoplastic |
| Gross weight |
579 g |
General data - Features
| Manual release |
Yes |
| Number of actuating directions |
4 |
| Number of auxiliary contacts |
1 |
| Number of safety contacts |
2 |
| Number of cable glands |
2 |
Safety classification
| Standards |
EN ISO 13849-1 |
| Performance Level, up to |
c |
| Category |
1 |
| B10D Normally-closed contact (NC) |
2,000,000 Operations |
| Note |
Electrical life on request. |
| B10D Normally-open contact (NO) |
1,000,000 Operations |
| Note |
at 10% Ie and ohmic load |
| Mission time |
20 Year(s) |
Safety classification - Fault exclusion
| Please note: |
Can be used when fault exclusion for dangerous damage to the 1-channel mechanism is permissible and sufficient protection against manipulation is guaranteed. |
| Performance Level, up to |
d |
| Category |
3 |
| Note |
for 2-channel use and with suitable logic unit. |
| Mission time |
20 Year(s) |
Mechanical data
| Mechanical lifetime, minimum |
1,000,000 Operations |
| Holding force FZh in accordance with EN ISO 14119 |
1,950 N |
| Holding force Fmax, maximum |
2,550 N |
| Latching force |
20 N |
| Positive break force, minimum |
20 N |
| Actuating speed, maximum |
0.3 m/s |
| Mounting |
Screws |
| Type of the fixing screws |
2x M5 |
Mechanical data - Connection technique
| Cable entry |
2 x M20 x 1,5 |
| Termination |
Screw terminals |
| Cable section, minimum |
0.5 mm² |
| Cable section, maximum |
1.5 mm² |
| Note |
All indications including the conductor ferrules. |
Mechanical data - Dimensions
| Length of sensor |
41 mm |
| Width of sensor |
52 mm |
| Height of sensor |
178 mm |
Ambient conditions
| IP Degree of protection |
IP65 IP67 |
| Ambient temperature |
-25 ... +55 °C |
| Note (Relative humidity) |
non-condensing non-icing |
| Protection class |
II |
Ambient conditions - Insulation values
| Rated insulation voltage Ui |
250 VAC |
| Rated impulse withstand voltage Uimp |
4 kV |
Electrical data
| Thermal test current |
4 A |
| Rated control voltage |
24 VDC |
| Required rated short-circuit current |
1,000 A |
| Electrical power consumption, maximum |
8.5 W |
| Switching element |
Magnet: 1 NO Contact, 1 NC contact / Actuator: 1 NC contact |
| Switching principle |
slow action, positive break NC contact |
| Maximale Schalthäufigkeit |
1,200 /h |
| Material of the contacts, electrical |
Silver |
Electrical data - Magnet control
| Magnet switch-on time |
100 % |
| Test pulse duration, maximum |
5 ms |
| Test pulse interval, minimum |
50 ms |
Electrical data - Safety contacts
| Voltage, Utilisation category AC-15 |
230 VAC |
| Current, Utilisation category AC-15 |
4 A |
| Voltage, Utilisation category DC-13 |
24 VDC |
| Current, Utilisation category DC-13 |
4 A |
Electrical data - Auxiliary contacts
| Voltage, Utilisation category AC-15 |
230 VAC |
| Current, Utilisation category AC-15 |
4 A |
| Voltage, Utilisation category DC-13 |
24 VDC |
| Current, Utilisation category DC-13 |
4 A |
Other data
| Note (applications) |
sliding safety guard removable guard hinged safety guard |
Scope of delivery
| Scope of delivery |
Actuator must be ordered separately. |
Note
| Note (General) |
Interlocks with the power to lock principle may only be used in special cases after a thorough evaluation of the accident risk, since the guarding device can immediately be opened on failure of the electrical power supply or when the main switch is opened. |
Language filter
Datasheet
Operating instructions (supplementary sheet/quick guide)
UL Certificate
SISTEMA-VDMA library
Download the latest version of Adobe Reader
Product picture (catalogue individual photo)
ID: kazm1f76
| 584.5 kB | .jpg | 352.778 x 642.7610000000001 mm - 1000 x 1822 px - 72 dpi
| 78.6 kB | .png | 74.083 x 134.761 mm - 210 x 382 px - 72 dpi
| 27.4 kB | .png | 74.083 x 74.083 mm - 210 x 210 px - 72 dpi
| 7.2 MB | .png | 169.333 x 308.52500000000003 mm - 2000 x 3644 px - 300 dpi
| 28.1 kB | .jpg | 67.733 x 123.47200000000001 mm - 192 x 350 px - 72 dpi
Dimensional drawing basic component
Schmersal, Inc., 15 Skyline Drive, NY 10532 Hawthorne
The details and data referred to have been carefully checked. Images may diverge from original. Further technical data can be found in the manual. Technical amendments and errors possible.
Generated at: 4/24/2026, 9:38 AM