TFH232-11UEDR
| Product type description: TFH 232(1) |
| (1) | |
| 11UEDR | 1 NO contact / 1 NC contact |
| 22UEDR | 2 NO contacts/2 NC contact |
- 2 Contacts
- 1 Cable entry M 20 x 1.5
- Protective shield with wide opening
- Low operating height of pedal
- High level of stability
Ordering data
| Product type description |
TFH232-11UEDR |
| Article number (order number) |
151181536 |
| eCl@ss number, version 12.0 |
27-37-12-18 |
| eCl@ss number, version 11.0 |
27-37-12-18 |
| eCl@ss number, version 9.0 |
27-37-12-18 |
| ETIM number, version 7.0 |
EC001258 |
| ETIM number, version 6.0 |
EC001258 |
Approvals - Standards
| Certificates |
cULus CCC |
General data
| Standards |
BG-GS-ET-15 DIN VDE 0660-200 EN IEC 60947-5-1 |
| Housing material |
Aluminium |
| Housing coating material |
powder-coated |
| Material of the housing cover |
Aluminium |
| Material of the pedal |
Glass-fibre, reinforced thermoplastic |
| Material of the protective shield |
Aluminium |
| Colour of the product |
White aluminum |
| Gross weight |
1,765 g |
General data - Features
| Suitable for EMERGENCY-OFF |
Yes |
| Probing possible |
Yes |
| Latching |
Yes |
Safety classification
| Standards |
EN ISO 13849-1 |
| Mission time |
20 Year(s) |
Safety classification - Safety outputs
| B10D Normally-closed contact (NC) |
100,000 Operations |
Mechanical data
| Mechanical lifetime, minimum |
1,000,000 Operations |
Mechanical data - Connection technique
| Termination |
Screw terminals M20 x 1.5 |
| Cable section, maximum |
2.5 mm² |
| Note |
All indications including the conductor ferrules. |
Mechanical data - Dimensions
| Width |
170 mm |
| Height |
189 mm |
| Depth |
274 mm |
Ambient conditions
| Degree of protection |
IP65 |
| Ambient temperature |
-25 ... +60 °C |
| Storage and transport temperature |
-25 ... +85 °C |
| Relative humidity, minimum |
30 % |
| Relative humidity, maximum |
95 % |
| Note (Relative humidity) |
non-condensing non-icing |
| Resistance to vibrations |
10 … 150 Hz, amplitude 0.35 mm / 5 g |
| Restistance to shock |
30 g / 11 ms |
Ambient conditions - Insulation values
| Rated insulation voltage Ui |
500 V |
| Rated impulse withstand voltage Uimp |
6 kV |
| Overvoltage category |
III |
| Degree of pollution |
3 |
Electrical data
| Thermal test current |
10 A |
| Required rated short-circuit current |
1,000 A |
| Utilisation category AC-15 |
230 VAC |
| Utilisation category AC-15 |
4 A |
| Utilisation category DC-13 |
24 VDC |
| Utilisation category DC-13 |
1 A |
| Switching element |
NO contact, NC contact |
| Switching principle |
Slow action |
| Maximale Schalthäufigkeit |
3,600 /h |
Language filter
Datasheet
Operating instructions and Declaration of conformity
UL Certificate
CCC certification
Brochure
SISTEMA-VDMA library
Download the latest version of Adobe Reader
Product picture (catalogue individual photo)
ID: ktfh-f02
| 342.8 kB | .jpg | 352.778 x 276.57800000000003 mm - 1000 x 784 px - 72 dpi
| 28.2 kB | .png | 74.083 x 58.208000000000006 mm - 210 x 165 px - 72 dpi
| 37.7 kB | .jpg | 123.47200000000001 x 96.661 mm - 350 x 274 px - 72 dpi
| 36.0 kB | .png | 74.083 x 74.083 mm - 210 x 210 px - 72 dpi
| 3.5 MB | .png | 169.333 x 132.757 mm - 2000 x 1568 px - 300 dpi