SLG440COM-ER-0500-02-H
| Product type description: SLG440COM-ER-(1) |
| (1) | |
| 0500-02 | Distance between outermost beams 500 mm, 2-beam, Range 0.3 m ... 12 m |
| 0500-02-H | Distance between outermost beams 500 mm, 2-beam, Range 8 m ... 60 m* |
| 0800-03 | Distance between outermost beams 800 mm, 3-beam, Range 0.3 m ... 12 m |
| 0800-03-H | Distance between outermost beams 800 mm, 3-beam, Range 8 m ... 60 m* |
| 0900-04 | Distance between outermost beams 900 mm, 4-beam, Range 0.3 m ... 12 m |
| 0900-04-H | Distance between outermost beams 900 mm, 4-beam, Range 8 m ... 60 m* |
| (*) | |
| typically 70 m | |
- Safety type 4 in accordance with IEC 61496-1
- Status and diagnostics via App with bluetooth
- User-friendly parameter setting, no tools required
- Reliable safety concept in case of interferences (EMC, welding sparks)
- Process safety with highest availability
- active integrated set-up tool
- optional degree of protection IP69 with protective enclosure (accessories)
Ordering data
| Product type description |
SLG440COM-ER-0500-02-H |
| Article number (order number) |
103054126 |
| EAN (European Article Number) |
4030661638218 |
General data
| Standards |
CLC/TS 61496-2 EN IEC 61496-2 EN IEC 61496-1 |
| Note (Software Version) |
as of 2024 Version 4.0 |
| Housing material |
Aluminium |
| Reaction time, maximum |
10 ms |
| Gross weight |
900 g |
| Bluetooth transmission power, maximum |
2 µW |
| Bluetooth transmission frequency |
2.400 … 2.483 GHz |
| Radiation emission level to EN 12198-1 |
Category 0 |
| Risk group classification of lamp systems to EN 62471 |
free group |
General data - Features
| Restart interlock (manual reset) |
Yes |
| Integral system diagnostics, status |
Yes |
| Integral system diagnostics |
Yes |
| Number of fail-safe digital outputs |
2 |
| Number of beams |
2 |
Safety classification
| Standards |
EN ISO 13849-1 EN IEC 62061 |
| Performance Level, up to |
e |
| Category |
4 |
| PFH value |
8.05 x 10⁻⁹ /h |
| Safety Integrity Level (SIL), suitable for applications in |
3 |
| Mission time |
20 Year(s) |
| Safety type in accordance with IEC 61496-1 |
4 |
Mechanical data
| Detection ability for test bodies at v = 1.6 m/s |
500 mm |
| Height of the protection field |
500 mm |
| Range, protection field, minimum |
8 m |
| Range, protection field, maximum |
60 m |
| Wave length of the laserdiode |
880 nm |
Mechanical data - Connection technique
| Length of cable |
100 m |
| Termination |
Connector |
| Terminal connector, Recipient |
Connector plug M12, 5-pole |
| Terminal, Connector, Transmitter |
Connector plug M12, 4-pole |
Mechanical data - Dimensions
| Length of sensor |
33 mm |
| Width of sensor |
27.8 mm |
| Height of sensor |
571 mm |
Ambient conditions
| Degree of protection |
IP67 |
| Ambient temperature |
-10 ... +50 °C |
| Storage and transport temperature |
-25 ... +70 °C |
| Resistance to vibrations |
10 … 55 Hz |
| Restistance to shock |
10 g, 16 ms, to EN 60028-2-29 |
| Protection class |
III |
Electrical data
| Operating voltage |
24 VDC -20 % / +20 % ((PELV) supply unit Imax 1.0 A, according to EN 60204 (power failure ≤ 20 ms)) |
| Rated operating voltage |
24 VDC |
| Rated operating current, Emitter |
200 mA |
| Rated operating current, Receiver |
700 mA |
Electrical data - Control inputs
| Designation, Control inputs |
Release / restart interlock |
| Actuation time for manual start |
100 … 1500 ms |
Electrical data - Safety digital outputs
| Designation, Safety outputs |
OSSD 1 and OSSD 2 |
| Output current, (fail-safe output), maximum |
0.25 A |
| Design of control elements |
OSSD, short-circuit proof, p-type |
| Leakage current Ir, maximum |
1 mA |
| Test pulse interval, typical |
750 ms |
| Test pulse duration, maximum |
0.15 ms |
| Classification ZVEI CB24I, Source |
C2 |
| Classification ZVEI CB24I, Sink |
C1 C2 |
| Load capacity, maximum |
0.05 µF |
| Load inductance, maximum |
2 H |
| Note |
The load inductance generates an induced voltage during the switch-off, which compromises the downstream components (sparkquenching element). |
| Switching voltage |
15 … 26.4 V (HIGH) 0 … 2 V (LOW) |
| Note |
According to EN 61131-2 |
| Note |
In case of failure, the leakage current flows to the OSSD cable. The downstream control element must recognise this state as LOW. A safety PLC must detect this state. |
LED status display - LED 01
| LED status |
OSSD ON, OSSD OFF, Restart interlock, Error, Parameter setting, Alignment kit, Indication of signal quality |
| LED position |
Receiver |
LED status display - LED 02
| LED status |
transmitting and status |
| LED position |
Emitter |
Other data
| Note (applications) |
protective mode/automatic, restart interlock, setting mode |
Pin assignment
| Connection |
Receiver |
| PIN 1 |
24 VDC power supply |
| PIN 2 |
OSSD 1 Safety output 1 |
| PIN 3 |
0 VDC Power supply |
| PIN 4 |
OSSD 2 Safety output 2 |
| PIN 5 |
Release/restart interlock Acknowledgement restart interlock |
| Connection |
Emitter |
| PIN 1 |
24 VDC power supply |
| PIN 2 |
Do not connect a signal (do not wire) |
| PIN 3 |
0 VDC power supply |
| PIN 4 |
Do not connect a signal (do not wire) |
Scope of delivery
| Scope of delivery |
Kit with 2 mounting angles |
Accessory
| Recommended safety switchgear |
SRB-E 301 |
Language filter
Datasheet
Operating instructions and Declaration of conformity
Brochure
SISTEMA-VDMA library
Download the latest version of Adobe Reader
Product picture (catalogue individual photo)
ID: kslc4f67
| 16.9 kB | .jpg | 79.72800000000001 x 273.75600000000003 mm - 226 x 776 px - 72 dpi
| 750.9 kB | .jpg | 352.778 x 1212.144 mm - 1000 x 3436 px - 72 dpi
| 67.7 kB | .png | 74.083 x 254.353 mm - 210 x 721 px - 72 dpi
| 22.9 kB | .jpg | 35.983000000000004 x 123.47200000000001 mm - 102 x 350 px - 72 dpi
| 12.0 kB | .png | 74.083 x 74.083 mm - 210 x 210 px - 72 dpi
| 7.0 MB | .png | 145.143 x 498.783 mm - 2000 x 6873 px - 350 dpi
Dimensional drawing basic component
Contact arrangement
K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, 42279 Wuppertal
The details and data referred to have been carefully checked. Images may diverge from original. Further technical data can be found in the manual. Technical amendments and errors possible.
Generated at: 15/04/2026, 06:17