SD-I-DP-V0-2 PROFIBUS-GATEWAY
SD-I-DP-V0-2 PROFIBUS-GATEWAY
Downloads
- PROFIBUS Gateway SD-I-DP-V0-2 to convert serial diagnostic signals to the PROFIBUS DP protocol
- The PROFIBUS Gateway SD-I-DP-V0-2 is a PROFIBUS slave
- Protection class IP 10 device for control cabinet mounting, for standard DIN rails
Ordering data
| Product type description |
SD-I-DP-V0-2 PROFIBUS-GATEWAY |
| Article number (order number) |
101192805 |
| EAN (European Article Number) |
4030661353951 |
| eCl@ss number, version 12.0 |
27-23-02-06 |
| eCl@ss number, version 11.0 |
27-23-02-06 |
| eCl@ss number, version 9.0 |
27-23-02-08 |
| ETIM number, version 7.0 |
EC001099 |
| ETIM number, version 6.0 |
EC001099 |
General data
| Gross weight |
120 g |
General data - Features
| Integral system diagnostics, status |
Yes |
| Number of LEDs |
4 |
Mechanical data
| Mounting |
Snaps onto standard DIN rail to EN 60715 |
Mechanical data - Connection technique
| Termination |
Cage clamps |
Mechanical data - Dimensions
| Width |
50 mm |
| Height |
72 mm |
| Depth |
97 mm |
Ambient conditions
| Degree of protection of the enclosure |
IP10 |
| Ambient temperature |
-5 ... +55 °C |
| Storage and transport temperature |
-25 ... +85 °C |
| Resistance to vibrations |
5 ... 9 Hz, Amplitude 3.5 mm 9 ... 150 Hz, with 1 g |
| Restistance to shock |
15 g / 11 ms |
Ambient conditions - Insulation values
| Rated insulation voltage Ui |
32 V |
| Rated impulse withstand voltage Uimp |
0.5 kV |
| Overvoltage category |
II |
| Degree of pollution |
2 |
Electrical data
| Operating voltage |
24 VDC -15 % / +20 % |
| Rated operating voltage |
24 VDC |
| Operating current |
250 mA |
Status indication
| Note (LED switching conditions display) |
ON permanent light green: supply voltage present PB Flashing signal: PROFIBUS initialisation PB Permanent light red: PROFIBUS error SD Flashing signal: = SD gateway initialisation SD Permanent light Red: = SD Gateway fault |
Other data
| Note (applications) |
Safety sensor Guard system |
Note
| Note (General) |
Detailed functions, see programming and configuration manual of the SD Gateway |
Wiring example
| Note (Wiring diagram) |
Serial diagnostics of series-wired safety sensors/solenoid interlocks Devices with serial diagnostic option: AZ 200, AZM 200, CSS 30S, CSS 34, MZM 100 |
Language filter
Datasheet
Mounting and wiring instructions
Declaration of conformity (EC)
Wiring example (electr. wiring)
Brochure
Download the latest version of Adobe Reader
Product picture (catalogue individual photo)
ID: kpbsdf02
| 1.2 MB | .jpg | 352.778 x 599.017 mm - 1000 x 1698 px - 72 dpi
| 86.6 kB | .png | 74.083 x 125.58900000000001 mm - 210 x 356 px - 72 dpi
| 56.3 kB | .jpg | 72.672 x 123.47200000000001 mm - 206 x 350 px - 72 dpi
| 51.6 kB | .png | 74.083 x 74.083 mm - 210 x 210 px - 72 dpi
| 11.1 MB | .png | 169.333 x 287.613 mm - 2000 x 3397 px - 300 dpi
Dimensional drawing basic component
Wiring example
Video ID: SD-Interface-Mr-Safety
K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, 42279 Wuppertal
The details and data referred to have been carefully checked. Images may diverge from original. Further technical data can be found in the manual. Technical amendments and errors possible.
Generated at: 20/04/2026, 15:31