PS116-T12-ST-J203
- connector plug M12, 8-pole
- only for positioning tasks
- Thermoplastic enclosure
- Symmetric enclosure
- Lever angle adjustable in 15° steps
- Protection class IP66, IP67
- Actuator heads can be repositioned by 8 x 45°
- Design to EN 50047
Ordering data
| Product type description |
PS116-T12-ST-J203 |
| Article number (order number) |
103010001 |
| EAN (European Article Number) |
4030661468693 |
| eCl@ss number, version 12.0 |
27-27-06-01 |
| eCl@ss number, version 11.0 |
27-27-06-01 |
| eCl@ss number, version 9.0 |
27-27-06-01 |
| ETIM number, version 7.0 |
EC000030 |
| ETIM number, version 6.0 |
EC000030 |
Approvals - Standards
| Certificates |
cULus CCC |
General data
| Standards |
EN IEC 60947-5-1 |
| Housing construction form |
Norm construction design |
| Housing material |
Plastic, glass-fibre reinforced thermoplastic, zinc die-cast, chromated |
| Active area |
Metal film |
| Gross weight |
122 g |
General data - Features
| Number of normally closed (NC) |
2 |
| Number of normally open (NO) |
1 |
Mechanical data
| Actuating element |
Rod lever J200 |
| Mechanical lifetime, minimum |
10,000,000 Operations |
| Positive break force, minimum |
40 N |
| Actuating speed, minimum |
60 mm/min |
| Actuating speed, maximum |
1 m/s |
| Actuating torque, minimum |
0.2 Nm |
| Positive break torque |
0.6 Nm |
Mechanical data - Connection technique
| Connector position |
Bottom |
| Termination |
Connector M12, 6-pole |
| Number of cable wires |
6 |
| Wire cross-section |
0.5 mm2 |
| Terminal (mechanical) |
bottom |
Mechanical data - Dimensions
| Length x Width x Height |
Height of sensor: 169 mm (rod centre) |
| Length of sensor |
16.6 mm |
| Width of sensor |
31 mm |
| Diameter of the Rod |
6 mm |
| Length of the lever |
200 mm |
Ambient conditions
| Degree of protection |
IP66 IP67 |
| Ambient temperature |
-30 ... +80 °C |
| Protection class |
II |
Ambient conditions - Insulation values
| Rated insulation voltage Ui |
300 V |
| Rated impulse withstand voltage Uimp |
4 kV |
| Degree of pollution |
3 |
Electrical data
| Required rated short-circuit current |
400 A |
| Utilisation category AC-15 |
240 VAC |
| Utilisation category AC-15 |
1.5 A |
| Utilisation category DC-13 |
24 VDC |
| Utilisation category DC-13 |
1.5 A |
| Switching element |
1 NO contact, 2 NC contacts |
| Switching principle |
Slow action |
| Bounce duration, maximum |
3 ms |
| Maximale Schalthäufigkeit |
5,000 /h |
| Switchover time, maximum |
5.5 ms |
| Material of the contacts, electrical |
Silver |
Language filter
Datasheet
Operating instructions (supplementary sheet/quick guide)
UL Certificate
CCC certification
Brochure
Download the latest version of Adobe Reader
Product picture (catalogue individual photo)
ID: kps1jf12
| 748.1 kB | .jpg | 352.778 x 1131.006 mm - 1000 x 3206 px - 72 dpi
| 89.2 kB | .png | 74.083 x 237.419 mm - 210 x 673 px - 72 dpi
| 14.0 kB | .jpg | 38.453 x 123.47200000000001 mm - 109 x 350 px - 72 dpi
| 10.3 kB | .png | 74.083 x 74.083 mm - 210 x 210 px - 72 dpi
| 6.9 MB | .png | 169.333 x 542.967 mm - 2000 x 6413 px - 300 dpi
Dimensional drawing basic component
Dimensional drawing actuator
Switch travel diagram
| EU Declaration of Conformity | ![]() |
| Original | K.A. Schmersal GmbH & Co. KG Möddinghofe 30 42279 Wuppertal Germany Internet: www.schmersal.com |
| Declaration: | We hereby certify that the hereafter described components both in their basic design and construction conform to the applicable European Directives. |
| Name of the component: | PS116, PS215, PS216, PS226, PS315, PS316 |
| Type: | See ordering code |
| Description of the component: | Position switch |
| Relevant Directives: | Low Voltage Directive | 2014/35/EU |
| RoHS-Directive | 2011/65/EU |
| Applied standards: | EN 60947-5-1:2017 |
| Person authorised for the compilation of the technical documentation: | Oliver Wacker Möddinghofe 30 42279 Wuppertal |
| Place and date of issue: | Wuppertal, March 3, 2021 |
![]() |
| Authorised signature Philip Schmersal Managing Director |
| UK Declaration of Conformity | ![]() |
| Company: | K.A. Schmersal GmbH & Co. KG Möddinghofe 30 42279 Wuppertal Germany Internet: www.schmersal.com |
| Declaration: | We hereby, under sole responsibility, certify that the hereafter described components both in their basic design and construction conform to the relevant statutory requirements, regulations and designated standards of the United Kingdom. |
| Name of the component: | PS116, PS215, PS216, PS226, PS315, PS316 |
| Type: | See ordering code |
| Description of the component: | Position switch |
| Relevant legislation: | Electrical Equipment (Safety) Regulations | 2016 |
| The Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations | 2012 |
| Designated standards: | EN 60947-5-1:2017 |
| UK-Importer / Person authorised for the compilation of the technical documentation: | Schmersal UK Ltd. Paul Kenney Unit 1, Sparrowhawk Close Enigma Business Park Malvern, Worcestershire, WR14 1GL |
| Place and date of issue: | Wuppertal, August 19, 2021 |
![]() |
| Authorised signature Philip Schmersal Managing Director |
K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, 42279 Wuppertal
The details and data referred to have been carefully checked. Images may diverge from original. Further technical data can be found in the manual. Technical amendments and errors possible.
Generated at: 21/04/2026, 00:30